{"id":2897,"date":"2025-12-02T09:00:00","date_gmt":"2025-12-02T09:00:00","guid":{"rendered":"https:\/\/www.gasyco.com\/staging\/linde-hungary-gas-analysis\/"},"modified":"2026-10-20T15:35:36","modified_gmt":"2026-10-20T15:35:36","slug":"linde-hungary-gas-analysis","status":"publish","type":"post","link":"https:\/\/www.gasyco.com\/en\/linde-hungary-gas-analysis\/","title":{"rendered":"Six months of test installations with Linde Hungary: what continuous gas analysis shows"},"content":{"rendered":"<p class=\"wp-block-paragraph\">We are proud to see the clear impact of the Gasyco gas analyser across multiple customer test installations over the past six months. Together with Linde Hungary, we reviewed key insights and challenges \u2014 confirming how essential continuous gas analysis has become for reliable and consistent welding quality.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Continuous gas analysis is not a \u201cnice-to-have\u201d \u2014 it is a decisive factor for process reliability and weld quality.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Over the past six months, the Gasyco GmbH gas analyser has been installed at several customer sites. Last week, I joined Ioannis Maitos and the team from Linde Hungary, K\u00e1roly Abaffy and G\u00e1bor Feh\u00e9rv\u00e1ri, to review the collected insights, challenges and opportunities in a series of concluding on-site discussions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The feedback clearly showed how essential transparency in gas supply truly is. The most frequently observed issues included moisture ingress during longer downtimes caused by minor leaks in the pipeline system, fluctuations in gas concentration during operation, and changes in mixture composition due to diffusion through older mixer membranes after standstill.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is exactly where continuous gas analysis delivers significant value: early detection of deviations before they lead to defective welds and scrap; real-time quality assurance across the entire welding process; predictive maintenance of mechanical gas mixers; automatic calibration and data logging, enabling full traceability for customers and auditors.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A key insight: even customers who saw no issues during the test period immediately recognised the value of transparency, documentation and automated calibration \u2014 all becoming increasingly important competitive differentiators.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A big thank you to the Linde Hungary team for their commitment, on-site support and strong engagement for advancing gas analysis.<\/p>\n<cite><span class=\"translation-block\">Maximilian Fischer, Managing Director, Gasyco GmbH<\/span><\/cite><\/blockquote>","protected":false},"excerpt":{"rendered":"<p>Moisture ingress after downtime, fluctuating concentrations, diffusion through old membranes: findings from several customer installations.<\/p>","protected":false},"author":1,"featured_media":2405,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"news_inhalt":[18],"news_rubrik":[26],"news_reihe":[],"news_thema":[44,48],"class_list":["post-2897","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-unkategorisiert"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/posts\/2897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/comments?post=2897"}],"version-history":[{"count":1,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/posts\/2897\/revisions"}],"predecessor-version":[{"id":3002,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/posts\/2897\/revisions\/3002"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/media\/2405"}],"wp:attachment":[{"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/media?parent=2897"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/categories?post=2897"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/tags?post=2897"},{"taxonomy":"news_inhalt","embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/news_inhalt?post=2897"},{"taxonomy":"news_rubrik","embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/news_rubrik?post=2897"},{"taxonomy":"news_reihe","embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/news_reihe?post=2897"},{"taxonomy":"news_thema","embeddable":true,"href":"https:\/\/www.gasyco.com\/en\/wp-json\/wp\/v2\/news_thema?post=2897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}