Opens in a new tab

Gas Mixer GAMI

The digital gas mixer for demanding processes: precise, stable and flexibly configurable. With intelligent control, remote access and optional analysis for maximum control over your gas mixture.

Applications by industry
Gas Mixer GAMI
Standard flow0 – 5,000 ln/min
Gas inletsflexibly configurable
Mixing rangeppm to %
Operating principleDigital mass flow controllers (MFC)
Operating modesPressure & flow control
Analysisoptionally integrated
Operation10.1" touchscreen | Remote
ConnectivityLTE | LAN | USB | Cloud
GAMI

Precise, stable, flexibly configurable.

With the GAMI you get an instrument that meets the highest demands for precision and stability. Thanks to a flexibly adjustable number of gas inlets, gas mixtures can be produced exactly to your individual requirements.

The integrated digital mass flow controllers (MFC) ensure reliable accuracy, stable processes and excellent reproducibility. Whether you are filling a buffer tank or supplying directly – you have full control. Inlet and outlet pressure are monitored as standard, so critical pressure deviations are detected early and can be integrated into process monitoring. The total flow ranges from 0 to 5,000 ln/min at an inlet pressure of 0.2 – 10 barg.

The clearly laid-out touchscreen allows intuitive operation; external start/stop signals can also be integrated. In addition, convenient remote access is available, enabling control, monitoring and data analysis from a distance.

For the highest process reliability, the GAMI offers continuous gas analysis on request. The integrated data logger records all parameters automatically; with Gasyco Connect you get a dashboard and reporting for your quality documentation – with Connect Enterprise also integrated into your existing IT infrastructure.

Comparison

More control over your gas mixture

A mechanical mixer can set a gas mixture – but without analysis it cannot prove that the mixture stays correct over time. With the GASYCO analyser, the actual gas quality becomes continuously visible and can be documented. The digital GASYCO gas mixer combines this transparency with active control, recipe management, data recording and optional cloud connection.

Requirement
Mechanical mixerMechanical
Mechanical mixer + GASYCO analysisMechanical + analysis
GasycoDigital GASYCO gas mixerGASYCO digital
Auditable and monitored gas mixtures
Alarms on limit deviations
Mixtures of 3 or more gases
Frequently changing recipes
ppm doping (e.g. O₂ in Ar)
Producing specialty and test gases on site
Remote access and digital operation
Cloud reporting and data export
Integration into plant control / PLC
Flexibility and reproducibility for laboratory & R&D
Inlet and outlet pressure monitoring
possible, but without ongoing proof of the actual gas quality
monitored and verifiable with the GASYCO analyser
actively controlled, and can be monitored and documented, with the digital GASYCO gas mixer
possible to a limited extent, depending on application, tolerance and operating effort
not suitable or not practical to implement
Technical data

Modular design. Configured exactly for your gases.

Total flow
0 – 5,000 ln/minexpandable
Gas temperature
0 – 50 °Cexpandable
Inlet pressure
0.2 – 10 bargexpandable
Outlet pressure
0 – 9 bargexpandable
Mixing ratios
ppm and %
Accuracy of the flow controllers
± 0.3 % of full scale plus ± 0.5 % of reading
Operating principle
separate digital control of the individual gas streams
Operating modes
pressure or flow control
Versions
with or without integrated analysis
Number of gases
unlimited
Dimensions
1000 × 600 × 250 mm
Weight
60 kg (depending on configuration)
Degree of protection
IP40
Ambient humidity
0 – 95 %rH, non-condensing
Gas connections, mixer
Compression fittings 12 mm · cutting ring fittings 28 mm
Gas connections, analysis
Compression fittings 6 mm
Power supply
100 – 240 VAC, 50 – 60 Hz, 1 A
CO₂ | O₂
ppm and %expandable
H₂ | He
0 – 100 %
H₂O – absolute residual moisture
0.1 ppm – 0.6 % (-80 – 0 °C dew point)expandable
NO
ppmexpandable
Custom configuration

This is our standard. Not your limit.

The flow rates, pressures, temperatures, gases and analyses in this table are our standard design. If your process needs more, we configure the mixer accordingly – on the same modular platform, with no development from scratch.

Higher flow rates
More gas inlets
Higher pressures
More gases & mixtures
Extended temperature ranges
Integrated analysis
Discuss your requirements
Key features

What every device can do as standard.

Pressure monitoring

for outlet and inlet

Remote access

Monitoring | Operation

Alarms

SMS and email alarm | Relay contacts

Flow controllers

High performance

Industrial controller

10.1" touchscreen

Gasyco Connect · Cloud Dashboard

Your gas mixer – in your browser at any time.

LTE, LAN and USB are built in as standard. With Gasyco Connect you can view and control your mixer from anywhere – with no software installation.

12 months free for new devices – after that, you decide whether to stay connected.

Mixture at a glance

Actual and setpoint values, flow rate and composition as a trend.

Remote access

Full functionality in any web browser.

Alarms

SMS and email in case of deviations or low supply pressure.

Documentation

Quality reports sent automatically by email – ready for audits.

Steady-Mix · built in, retrofit with Connect Plus

Mix steadily instead of filling in bursts.

Steady-Mix continuously adjusts the mixing output to your actual gas consumption. And the mixer stays ready for operation, even when the gas supply runs short.

Fewer starts mean fewer settling phases – and therefore a more consistent mixture.

Follows consumption

Long and steady instead of start-stop.

Learns your system

Buffer tank and pipework volumes are approximated automatically during operation.

Always within the control range

No controller leaves its control range – mixing accuracy is maintained.

Stays ready for operation

Early warning at low supply pressure, readiness and automatic restart.

Typical applications
  • ppm doping, e.g. oxygen in argon
  • Mixtures of three or more gases
  • Replacing premixed gas cylinders with on-site mixing
  • Processes with high reproducibility requirements
  • Applications with documentation, audit or customer requirements
  • Processes with remote monitoring, alarms or cloud reporting
  • Remote control for hazardous gases and environments
Frequently asked questions

The right questions. The right answers.

What is an MFC gas mixer?

An MFC gas mixer controls each gas with its own digital mass flow controller (MFC) and combines the gas streams in the set ratio. In the GAMI each gas stream is controlled digitally and separately, in pressure or flow control and with mixing ratios from ppm to per cent. The controllers achieve a typical MFC accuracy of ± 0.3 % of full scale plus ± 0.5 % of reading – which is why the correct design and sizing of each controller is decisive for the quality of the mixture.

What is the difference between a digital and a mechanical gas mixer?

A mechanical gas mixer can set a mixture, but without analysis it cannot prove that the mixture stays correct. The digital GAMI actively controls every gas stream, monitors inlet and outlet pressure, raises alarms by SMS, email or relay contact and records all values. You change recipes on the touchscreen or remotely – also for mixtures of three or more gases and ppm doping.

How many gases can the GAMI mix?

As many as you need. The number of gas inlets is configured for your process, and each gas gets its own flow controller. One example from our production: a mixer with five gas inlets and nine flow controllers in total.

Which flow rates and pressures does the GAMI cover?

As standard, 0 – 5,000 ln/min total flow at 0.2 – 10 barg inlet and 0 – 9 barg outlet pressure, gas temperature 0 – 50 °C. For very wide control ranges we use several graded flow controllers per gas – in one project this gave a turndown of up to 1:60,000, from 1 mln/min to 60 ln/min. We design higher flow rates and pressures on the same modular platform.

Is the GAMI suitable for corrosive or flammable gases such as hydrogen?

Yes, with the right design. For aggressive or corrosive gases and higher pressures we use capillary mass flow controllers whose sensor sits behind a stainless steel wall. We plan hydrogen and fuel gas systems on a project basis; if the process needs a safety-related shutdown, we combine the mixer with the SIL Gas Control SGC (SIL 1 to SIL 3 to IEC 61511) – as SGC Mix in a shared housing or as SGC Sense with integrated analysis.

Can the GAMI be integrated into a PLC or plant control system?

Yes. OPC UA and FTP are available as direct interfaces; in projects we have also implemented Modbus TCP, EtherCAT, PROFIBUS and PROFINET, among others. External start/stop signals, e.g. 24 V DC, can be integrated, and alarms are available as relay contacts in addition to SMS and email. LTE, LAN and USB are built in as standard.

Can the GAMI replace premixed gas cylinders?

Yes. The GAMI produces every recipe from ppm to per cent on site from the individual gases you already buy – for example shielding gas for welding, ppm doping such as oxygen in argon, or test and specialty gases in the lab. This saves cylinder logistics, waiting times and cylinder changes for every new mixture.

Do I need a buffer tank?

With fluctuating consumption, yes – unless the volume of the ring mains replaces it. As a rule of thumb for the initial design, the total buffer volume should be about one third to one half of the mixer output per minute. We recommend controlling directly to a target flow only when consumption is steady. Steady-Mix continuously adjusts the mixing output to your actual consumption – it is included in newly built devices, and existing systems receive it as an update with Connect Plus or Connect Enterprise.

Can the GAMI analyse and document the mixture itself?

Yes, with optional integrated gas analysis: CO₂ and O₂ in ppm and per cent, H₂ and He from 0 to 100 %, residual moisture and NO in the ppm range; further gases on request. The integrated data logger records all parameters; quality reports for audits are available in the Gasyco Dashboard. Where a GAMI is already in use, integrated analysis is more economical and more compact than a separate gas analyser.

Can an existing GAMI be extended later?

In most cases, yes. A mass flow controller can be replaced with one with a larger flow range, and additional gas lines or integrated analysis can be retrofitted – the deciding factor is the space in the housing. The modification is carried out by our technicians or trained distribution partners, and we configure the control system via the remote connection.

Downloads

Technical data sheet

Further documents are available for download in the customer area.

Contact

Let’s talk about your system.

From design to commissioning – we plan your gas supply as a connected complete system.