This example clearly shows how important complete gas analysis is in the production of forming gas. Our systems detect deviations in gas quality immediately – even before a system goes into operation.
We recently delivered a gas mixer for hydrogen and nitrogen to produce forming gas. The system was equipped with precise H₂ analysis, residual oxygen measurement in the low ppm range and residual moisture measurement – all to monitor the quality of the forming gas exactly.
Shortly after installation, the customer reported that the analysis was “measuring incorrectly”: the oxygen value fluctuated between 100 ppm and the sensor’s full-scale value of 2000 ppm – so the actual O₂ content was probably considerably higher. Residual moisture remained constantly above 300 ppm, although ISO 14175 allows a maximum of 40 ppm. Both values should actually be below 10 ppm to produce truly high-quality forming gas.
After some analysis, it turned out that the customer was using nitrogen from a PSA plant (pressure swing adsorption) – not N₂ 5.0 from cylinders or a tank. This made it clear that the required gas purity could not be achieved at all.
Our integrated gas analysis revealed the problem immediately, even before commissioning – preventing defective or improperly treated components from being produced.
My conclusion: comprehensive analysis of all gas parameters is not a luxury, but a central part of professional quality management. Only those who know what is really in the gas can ensure safe and reproducible processes in the long term.
Maximilian Fischer, Managing Director, Gasyco GmbH
Translated from German.